SPECIFICATIONS FOR GEN-PRO PORTABLE GEN-SETS, USING LOMBARDINI AIR COOLED, HEAVY DUTY, DIESEL ENGINES.

 

GENERATOR MODELS

SINGLE PHASE, 120/240 VOLTS, 60 HERTZ WITH DIESEL ENGINES

LOMBARDINI AIR COOLED ENGINES

GPNDL- 60E GPNDL- 120E
GENERATOR REGULATION ALL MODELS : PLUS OR MINUS 5% FROM NAMEPLATE RATING
FREQUENCY REGULATION ALL MODELS : PLUS OR MINUS 5% FROM NAMEPLATE RATING
"KLEEN-POWER"TM ALL MODELS : WAVEFORM DISTORTION AVERAGES 6% - 7%
ENGINE BRAND LOMBARDINI AIR COOLED LOMBARDINI AIR COOLED
ENGINE MODELS AND STYLE 6LD435 25LD425
PORTABLE PORTABLE
ENGINE STARTER

ELECTRIC

ELECTRIC

ENG. HP/3600 RPM 9.5 18.0
ENG. CU. CENTIMETER 401 851
ENGINE CYLINDERS 1 2
LOW OIL PROTECTION ALL MODELS : STANDARD ENGINE SHUT-DOWN PROTECTION
COLD START GLO-PLUGS NO NO
db(A) AT 7 METERS 85 92
FUEL TANK (GAL.) 4 GALLON (15 LITER) CROSSLINK POLYETHYLENE TANK 8 GALLON (30 LITER) CROSSLINK POLYETHYLENE TANK
3/4 LOAD RUN TIME (HRS.) 7.5 10
FUEL USE (GAL/HR) .52 .80
FULL PRESSURE OIL LUBE WITH SPIN-ON FILTER ALL MODELS : REPLACEABLE OIL FILTERS AND FULL PRESSURE OIL LUBRICATION ARE STANDARD EQUIPMENT
CODE G, ELECTRIC MOTOR STARTING POWER 1.5 HP 3 HP
BUILT-IN 2 WHEEL DOLLY OPTIONAL EQUIPMENT
MAIN CIRCUIT BREAKER ALL MODELS : MAIN LINE AUTOMATIC CIRCUIT BREAKER PROTECTING WINDINGS AND INDIVIDUAL CIRCUIT BREAKERS PROTECTING EACH RECEPTACLE.
VOLTMETER & HOURMETER ALL MODELS : STANDARD EQUIPMENT ON CONTROL PANEL
120 VOLT RECEPTACLES (4) NEMA 5-15R, 120 V., 20 AMP W/ GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)
(1) NEMA L5-30R, 30 AMP, 3-WIRE TWIST-LOCK
120/240 VOLT RECEPTACLE (1) NEMA L14-20R, 20 AMP (1) NEMA 14-50R, 50 AMP
LENGTH, INCHES 28 35
WIDTH, INCHES 22 24
HEIGHT, INCHES 23 26
NET WEIGHT (LBS.) 191 335
SHIP WEIGHT (LBS.) 207 350
CU. FT. AREA - SHIP BOX 10 16
 
GENERATOR DESIGN: Applications are for heavy duty, long running and abusive conditions.  A diesel engine will extend the normal life of a gasoline engine by 3 times, before normal engine repairs are required.  If the gen-set must run more than 6 hours per day, these diesel gen-sets should be considered.  The air cooled Lombardini driven generator is portable.  Part No G-12 two-wheel dolly kit is available for both units.  All heavy duty Gen-Pro features are available on these sets.  A 2-year limited warranty is offered on generators and a 3-year limited warranty is offered on Lombardini diesel engines.  These (2) generator models are the smart choice and the right choice for emergency power jobs that must run at long intervals.
 
Previous Features Accessories
Gillette Generators, Inc.
Copyright © 2006   All rights reserved.