MORE SPECIFICTATIONS

DIESEL GENERATOR MODELS WITH SINGLE & THREE PHASE KW/KVA RATINGS

1 PHASE MODELS

SPLD-150-1 SPJD-250-1 SPJD-350-1 SPJD-450-1 SPJD-550-1 SPJD-650-1
MAXIMUM KW OUTPUT @ 1 PHASE, 1.0 P.F. 15.0 25.0 35.0 45.0 55.0 64.0
STANDBY KW OUTPUT @ 1 PHASE, 1.0 P.F. 14.0 22.0 32.0 42.0 52.0 60.0

3 PHASE MODELS

SPLD-150-3 SPJD-250-3 SPJD-350-3 SPJD-450-3 SPJD-550-3 SPJD-650-3
MAXIMUM KW/KVA OUTPUT @ 3 PHASE, .8 P.F. 15.0/18.8 25.0/28.8 35.0/43.8 45.0/56.0 55.0/68.8 65.0/81.0
STANDBY KW/KVA OUTPUT @ 3 PHASE, .8 P.F. 14.0/17.5 22.0/27.5 30.0/40.0 42.0/53.0 52.0/65.0 62.0/77.5
ENGINE SPECIFICATIONS
ENGINE LOMBARDINI JOHN DEERE
ENGINE HP 25 48 48 80 80 97
ENGINE CYL. 4 4 4 5 5 5
ENGINE RPM 4 POLE, 1800 RPM
ENGINE PISTON AREA 1.7 L. 2.4 L. 2.4 L. 3.05 L. 3.05 L. 3.05 L.
ENGINE IDUCTION SYSTEM NATURALLY ASPIRATED TURBO-CHARGED INDUCTION SYSTEM ON ALL JOHN DEERE ENGINES
MUFFLERS FOR OPEN, STANDARD, & SUPER-SILENT HOUSINGS OPEN (NO ENCL.) HAS INDUSTRIAL MUFFLER FOR NORMAL EXHAUST SILENCING
STANDARD HOUSING HAS RESIDENTIAL MUFFLER FOR AVERAGE EXHAUST SILENCING
SUPER-SILENT HOUSING HAS RESIDENTIAL MUFFLER FOR ABOVE AVERAGE EXHAUST SILENCING.  SEE CRITICAL MUFFLER FOR ULTIMATE EXHAUST SILENCING.
ENGINE FUEL ABOVE 32°F = #2D DIESEL FUEL : BELOW 32°F = A 50-50 MIX OF #1D AND #2D DIESEL FUEL.  IT IS RECOMMENDED TO USE A BATTERY HEATER AND FUEL HEATER, BELOW 32ºF

CONTROL SPECIFICATIONS

CONTROLLER "SENTINEL-SCOUT" WITH ENG/GEN START-STOP CONTROLS
ENGINE & GENERATOR AUTO SHUT-DOWN PROTECTORS LOW OIL, OVER-SPEED, HIGH TEMPERATURE,& OVER-CRANK FAILURE SHUTDOWN PROTECTION. OVER-CRANK HAS (3) SEPARATE STARTING ATTEMPTS BEFORE SHUTDOWN.  SEE "SENTINEL-SCOUT" FOR ADDITIONAL INFO.
METER PACKAGE HOUR METER INCLUDED. FOR MORE REPORTING FUNCTIONS, SEE "SENTINEL III" DIGITAL CONTROLLER FOR FULL METERING AND CONTROL DETAILS
CIRCUIT BREAKER OPTIONAL EQUIPMENT DUE TO THE VARIETY OF REQUIREMENTS AT POINT OF FINAL INSTALLATION.  SEE CIRCUIT BREAKERS PAGE FOR MORE INFO
BATTERY CHARGER STANDARD EQUIPMENT.  SEE BATTERY CHARGERS FOR FULL DETAILS, PLUS NFPA-110
COMPLETE GENERATOR SET SPECIFICATIONS
WEATHER HOUSING ALL HOUSINGS ARE MADE OF "RUST-PROOFED" GALVANEEL STEEL AND SUITABLE FOR BAD WEATHER PROTECTION.  AIR BAFFLES AND SOUND PROOF FOAM ALLOWS SUPERIOR SOUND DEADENING BENEFITS.
OPEN DIMS LG X WI X HI 50"X34"X30" 68" LG X 36" WI X 40" HI 78" L X 42" W X 49" H
STD. ENCL. DIMS LG X WI X HI 67"X34"X36" 82" LG X 36" WI X 48" HI 94" L X 42" W X 53" H
S.S. ENCL. DIMS LG X WI X HI 67"X34"X36" 96" LG X 36" WI X 48" HI 110" X 42" X 53"
 

DETAIL SINGLE MODEL 4-PAGE SPECIFICATION SHEETS

SPLD-150, 60 & 50 HZ, 1 & 3 PHASE

SPJD-450, 60 & 50 HZ, 1 & 3 PHASE
SPJD-250, 60 & 50 HZ, 1 & 3 PHASE SPJD-550, 60 & 50 HZ, 1 & 3 PHASE
SPJD-350, 60 & 50 HZ, 1 & 3 PHASE SPJD-650, 60 & 50 HZ, 1 & 3 PHASE
ALL 60 HZ DIESEL COMBO SPECIFICATION SHEET

ALL 50 HZ DIESEL COMBO SPECIFICATION SHEET

 

SENTRY-PRO DIESEL WITH AUTOMATIC OPERATION : When normal power fails, SENTRY-PRO DIESEL automatically starts and supplies your selected emergency loads.  Upon return of normal power, SENTRY-PRO DIESEL automatically shuts down and returns emergency loads back to normal power.  These actions require no operator to be present. 

A TYPICAL "ENGINE START" ACTION IS AS FOLLOWS:
1.  A time delay of 10 second (adjustable) to engine crank (eliminates nuisance starts on normal power glitch losses).
2.  A (3) cycle engine crank occurs:  15 second engine crank, followed by 15 second engine rest.  after (3) crank attempts, a final shutdown occurs.  This action saves the starting battery and engine starter motor from overheat damage.  If engine doesn't start in (3) attempts, it becomes a permanent shutdown, & a service technician is required.
3.  A time delay to transfer, allows generator set to start, stabilize and warm-up before electric load is transferred to emergency generator power (adjustable).

A TYPICAL "ENGINE STOP" ACTION IS AS FOLLOWS:
1.  A time delay to retransfer, allows return of lost utility power to stabilize before re-transfer of electric load, back to utility power. (adjustable)
2.  A time delay to "engine cool down", allows load to be removed from gen-set, and engine runs un-loaded for a predetermined cool-down period. (adjustable)
3.  At any time an engine or generator would mal-function, the entire gen-set system would immediately shut down.  The fault must be corrected, the control system must be "Reset" and gen-set is ready to run again.

Please review SENTINEL-SCOUT to learn the full features and benefits of this digital controller allowing for a multitude of engine and generator protection controls.  This controller is installed only on 1800 RPM, 4-pole gen-sets.

The automatic transfer switch is not included with any 4-pole, 1800 RPM, standby generators, but rather, it is offered as a separate item, due to the many choices of different styles, voltages and designs.  A 100 amp through 1200 amp, UL-1008 certified auto transfer switch is available.  Our new "Service Entrance / Auto Transfer Switch" is  now available.  This device combines the required service entrance disconnect (a molded case circuit breaker) with the automatic transfer switch.  All pre-wired and installed into one enclosure.  This saves installation time and costs, over the two individual device methods of the past.  Also, view "Automatic Transfer Switch" for specifications on both standard automatic transfer switches and our new service entrance transfer switch.