UL–142 EXTENDED RUN SUB-BASE FUEL TANKS

FOR ALL SENTRY-PRO, SPD SERIES, EMERGENCY STANDBY GENERATOR SETS
Available for 24, 48 and 72 hour extended run times

 

EXTENDED RUN DIESEL FUEL TANK

Shown mounted below Model SPD-600-1-1 60 KW emergency standby generator system with model DWT-5, double wall, 24 hour run time diesel fuel tank.

...Need longer run capacity on Diesel fueled generator systems?

THEN DO THE JOB SAFELY AND PROPERLY WITH OUR ALL STEEL WELDED, SUB-BASE DIESEL FUEL TANKS

CERTIFICATIONS

  • UNDERWRITER’S LABORATORIES, STANDARD UL-142 STEEL ABOVE GROUND TANKS FOR FLAMMABLE AND COMBUSTION LIQUIDS
  • NFPA-37 STANDARD FOR INSTALLATION AND USE OF STATIONARY COMBUSTIBLE ENGINE AND GAS TURBINES.
  • NFPA-30 STANDARD FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS
  • NFPA-110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS

CONSTRUCTION

Tank is made of heavy gauge steel with reinforced steel box channel for generator support, full height gussets are provided at gen-set mounting holes and tested at 5000 lbs load. All tanks are pressure washed with an iron phosphate solution, then finished with an acrylic primer and enamel finish. Tank interior is coated with an additional solvent-based rust preventative. All tanks are final tested with 3 psi air pressure and leak checked to insure integrity of weld seams per UL-142 standards.

FEATURE AND BENEFITS

  • EMERGENCY PRESSURE VENTS: INSURES PROPER VENTING UNDER EXTREME AMBIENT HEAT CONDITIONS
  • ATMOSPHERIC VENT: ACCOMMODATES NORMAL VENTING
  • RAISED FUEL FILL: PROTECTS FROM OVERFILL AND PROVIDES LOCKABLE FILL COVER
  • FUEL LEVEL GAUGE: VISUAL INSPECTION PLUS ANNUNCIATES AT 50% LOW FUEL LEVEL CONDITION (NO AUTOMATIC SHUTDOWN)
  • LEAK DETECTION SWITCH (DOUBLE WALL TANKS ONLY): ANNUNCIATES FUEL LEAK AND AUTOMATICALLY SHUTS GEN-SET DOWN.
  • REMOVABLE GENERATOR END PANEL: PROVIDES FULL BASE WIDTH ACCESS FOR ELECTRICAL STUB-UP CONNECTION WORK
  • NOTE: ALWAYS CHECK YOUR LOCAL CODES FOR ANY SPECIAL APPROVAL TANKS THAT MAY BE REQUIRED IN YOUR AREA.
EXTENDED RUN DIESEL FUEL TANK

Shown mounted below model SPD-250-1-1, 25 KW emergency standby generator system with model DWT-4, single wall, 48 hour run time diesel fuel tank.

STANDARD DUAL WALL SUB-BASE TANKS FOR 15-130 KW DIESEL GEN-SETS
(SELF CONTAINMENT, "LEAK-PROOF" TANKS)

UL 142 Listed Generator Base Tanks

SENTRY-PRO

DIESEL MODELS

TANK PART NO.

FULL LOAD RUN HOURS

TANK CAPACITY

EM. VENT

TANK DIMENSIONS

ELECTRIC STUB-UP

SHIPPING WT.

LENGTH

WIDTH

HEIGHT

(60 HZ)

GAL.

LTR.

IN

MM

IN

MM

IN

MM

IN

MM

LBS.

KG

SPD-150

DWT-1

50.2

50

190

2

68

1727

36

915

11 279

12

305

531 241

DWT-2

84.6

85

320

2

68

1727

36

915

18 457

12

305

665 302

SPD-250

DWT-2

28.2

85

320

2

68

1727

36

915

18 457

12

305

665 302

DWT-3

56.3

169

640

3

68

1727

36

915

32 813

12

305

955 433

DWT-4

72.5

254

960

3

83

2100

36

915

36 914

18

457

1186 538

SPD-320

DWT-2

24.2

85

320

2

68

1727

36

915

18 457

12

305

665 302

DWT-3

48.3

169

640

3

68

1727

36

915

32 813

12

305

955 433

DWT-4

63.4

254

960

3

83

2100

36

915

36 914

12

305

1186 538

SPD-450

DWT-5

30.5

122

462

3

78

1981 42 1067 18 457

18

457

824 374

DWT-6

54.2

217

820

3

78

1981 42 1067 32 813

18

457

1155 524

DWT-7

81.3

325

1230

4

94

2400 42 1067 36 914

18

457

1425 646

SPD-600

DWT-5

27.1

122

462

3

78

1981 42 1067 18 457

18

457

824 374

DWT-6

48.1

217

820

3

78

1981 42 1067 32 813

18

457

1155 524

DWT-7

72.2

325

1230

4

94

2400 42 1067 36 914

18

457

1425 646

SPD-750

DWT-5

24.4

122

462

3

78

1981 42 1067 18 457

18

457

824 374

DWT-6

48.1

217

820

3

78

1981 42 1067 32 813

18

457

1155 524

DWT-8

72.4

362

1370

4

98

2500 42 1067 36 914

18

457

1466 665

SPD-1000

DWT-9

30.7

169

640

3

98

2489 48 1220 15 381

21

533

1071

486

DWT-10

52.4

288

1090

3

98

2489 48 1220 26 660

21

533

1341

608

DWT-12

72.0

396

1499

4

98

2489 48 1220 36 914

21

533

1585 719

SPD-1300

DWT-9

24.1

169

640

3

98

2489 48 1220 15 381

21

533

1071

486

DWT-11

48.3

338

1279

4

98

2489 48 1220 32 813

21

533

1477 670

DWT-13

72.1

505

1912

4

118

3000 48 1220 36 914

21

533

1822 826

All Sentry-Pro Diesel gen-sets have (3) choices of fuel tank capacities allowing an approximate average full load running time of 24, 48, or 72 hours. We find these (3) run time hours, to be the most popular requested sizes. However, larger gallon capacities giving longer run times for each gen-set model, is available upon request.

TANK DESCRIPTION: The Gillette Sentry-Pro dual wall, diesel fuel tank is a steel rectangular tank with a sealed, separately vented, integral fuel containment basin.

UL AND NATIONAL STANDARDS:
STANDARD UL 142: (UL listed under file no. MH17470) for dual wall steel aboveground tanks with flammable and combustible liquids.
STANDARD NFPA 30: for flammable and combustible liquids.
STANDARD NFPA 37: for installation and use of stationary combustible engine and gas turbines.
STANDARD NFPA 110 : for emergency and standby power systems.

CONSTRUCTION: All tanks are pressurized to 3 PSI and leak checked to ensure integrity of weld seams per UL 142 standards. Tank is constructed of heavy gauge steel and includes a reinforced steel box channel for generator support. Full height gussets are provided at gen-set mounting holes. Tanks are load rated at 5000 Lbs. per gen-set mounting point. The tank design has been tested extensively under conditions far in excess of normal use, to insure safe support of full generator weight. In addition, tanks are pressure washed with an iron phosphate solution and finished with an acrylic primer plus enamel paint. Tank interior is coated with a solvent based rust inhibitor.

STANDARD, GILLETTE, SENTRY-PRO SUB-BASE TANK FEATURES:
Emergency Pressure Relief Vent Caps: Meets or exceeds UL and NFPA requirements. This insures adequate venting and pressure relief for single wall tank (both inner and outer tank compartments for secondary containment tanks), under extreme emergency conditions.
Atmospheric Vent Cap: Accommodates normal venting (oversized 2" vent is raised above the fuel fill pipe).
Raised Fuel Fill: Includes a lockable flip top to prevent tampering and/or fuel contamination.
Fuel Level Gauge: Provides direct fuel level reading.
Low Fuel Level Switch: Annunciates a 50% low fuel level condition at gen-set control panel.
Leak Detection Switch: Annunciates a contained primary tank fuel leak at gen-set control panel. Note: This feature is for dual wall, secondary containment tanks only.
Removable Generator End Channel: Provides access to a full width, 12", 18", or 21" open electrical stub-up area.

OPTIONAL EQUIPMENT
(Note: All options need to be included in original order, as none are able to be field installed)

PART NO.

DESCRIPTION

3372

IMMERSION HEATER FOR SINGLE WALL TANK CAPACITIES 50-99 GAL., RATED AT 1000 WATTS, 120 VAC, 1 PHASE.

3376

IMMERSION HEATER FOR SINGLE WALL TANK CAPACITIES 100-125 GAL., RATED AT 2000 WATTS, 120 VAC, 1 PHASE.

3378

IMMERSION HEATER FOR SINGLE WALL TANK CAPACITIES 275-400 GAL., RATED AT 3000 WATTS, 120 VAC, 1 PHASE.

3379

IMMERSION HEATER FOR SINGLE WALL TANK CAPACITIES 450-600 GAL., RATED AT 4000 WATTS, 120 VAC, 1 PHASE.

3382

ACCESS PIPING FOR ABOVE (4) IMMERSION HEATERS TO BE USED ON DOUBLE WALL, SECONDARY CONTAINMENT TANKS. ADD THIS $247 LIST PRICE TO THE LIST PRICE OF SELECTED HEATER, FOR ALL DOUBLE WALL TANK SELECTIONS.

3177

DUAL (HIGH/LOW) FUEL LEVEL SWITCH. SPECIFY TANK PART NO. OR TANK HEIGHT AND FUEL LEVEL % AT ACTIVATION. EXAMPLE: HIGH FUEL LEVEL ANNUNCIATION AT 95% FULL, LOW FUEL LEVEL ANNUNCIATION AT 50% LEVEL.

2815

REMOVABLE LIFTING PLATES, FACILITATE LIFTING OF EMPTY TANK AND OPEN (NO ENCLOSURE) GENERATOR SET.

1991

STATE OF MASSACHUSETTES OPTION KIT FOR LOCAL TANK CODE REQUIREMENTS

1992

STATE OF NEW YORK OPTION KIT FOR LOCAL TANK CODE REQUIREMENTS

1995

STATE OF WISCONSIN (INDOOR) OPTION KIT FOR LOCAL TANK CODE REQUIREMENTS

1996

STATE OF WISCONSIN (OUTDOOR) OPTION KIT FOR LOCAL TANK CODE REQUIREMENTS

1997

CITY OF CHICAGO OPTION KIT FOR LOCAL CODE REQUIREMENTS

1998

CITY OF LOS ANGELES (FIRE DEPT.) OPTION KIT FOR LOCAL CODE REQUIREMENTS

(-)

STATE OF FLORIDA OPTION KIT FOR LOCAL TANK CODE REQUIREMENTS

Previous

Gillette Generators, Inc.