PART NO.
|
PART
|
DESCRIPTION FOR ITEMS, USED WITH ONLY 4-POLE 1800 RPM STANDBY SETS
|
CONSULT CIRCUIT BREAKER SHEET |
CIRCUIT BREAKER USED WITH 1 PHASE AND 3 PHASE GEN-SETS |
ALL SINGLE & THREE PHASE MAIN LINE CIRCUIT BREAKERS FROM 15 KW TO 200 KW IN 1800 RPM SETS, ARE SIZED TO THE INDIVIDUAL KW OUTPUT OF GENERATOR. SEE SEPARATE CIRCUIT BREAKER SHEET FOR SPECIFICATIONS. |
S-8 |
EXTERNAL PMG EXCITATION |
EXTERNAL PERMANENT MAGNET GENERATOR (PMG), COMPIES TO NAFPA 110 AND PROVIDES SUPERIOR ELECTRIC MOTOR STARTING PERFORMANCE. |
SEE FUEL TANK SHEET |
UL-142 CERTIFIED METAL SUB-BASE
FUEL TANKS |
THE NORMAL BASE MOUNTED, POLYETHYLENE FUEL TANKS, HAVE BEEN REPLACED WITH UL-142 CERTIFIED SINGLE WALL STEEL TANKS (STANDARD TANKS) AND DOUBLE WALL STEEL TANKS (LEAK PROOF TANKS), DUE TO INCREASING DEMAND FOR UL CERTIFIED TANKS. SEE SEPARATE FUEL TANK SHEET FOR SPECIFICATIONS. |
S-10A |
3/4" FLEXIBLE DRY FUEL LINE |
LPG OR NATURAL GAS LINE WITH 3/4" NPT FITTINGS FOR 15-60 KW, 12" LONG. |
| S-10B |
1" FLEXIBLE DRY FUEL LINE |
LPG OR NATURAL GAS LINE WITH 1" NPT FITTINGS FOR 85 KW, 12" LONG. |
S-10C |
1-1/4" FLEXIBLE DRY FUEL LINE |
LPG OR NATURAL GAS LINE WITH 1-1/4" NPT FITTINGS FOR 100 KW, 12" LONG. |
S-10D |
1-1/2" FLEXIBLE DRY FUEL LINE |
LPG OR NATURAL GAS LINE WITH 1-1/2" NPT FITTINGS FOR 125 KW, 12" LONG. |
S-12 |
ELECTRONIC GOVERNOR FOR DIESEL ENGINES |
ALLOWS CLOSE ENGINE SPEED AND FREQUENCY REGULATOIN TO 1/2%. NOTE ALL GM ENGINES HAVE ELECTRIC GOVERNORS. (15 KW THRU 60 KW) |
| S-13C |
ENGINE COOLANT HEATER W/ THERMO. |
COOLANT HEATER WITH ON-OFF THERMOSTAT, WARMS ENGINE FOR FASTER COLD WEATHER STARTS. USE ON 15.0 THRU 45.0 KW STANDBY SET. |
| S-13D |
ENGINE COOLANT HEATER W/ THERMO. |
COOLANT HEATER WITH ON-OFF THERMOSTAT, WARMS ENGINE FOR FASTER COLD WEATHER STARTS. USE ON 60.0 THRU 130.0 KW STANDBY SET. |
S-14 |
BATTERY HEATER
WITH THERMOSTAT |
HEATS BATTERY TO 60°F ON 120 V. NORMAL POWER, WHILE GEN-SET IS IN STANDBY MODE. |
| S-16B |
BATTERY CHARGER |
AUTOMATIC 2-STAGE BATTERY CHARGER, MAINTAING FULL BATTERY CHARGE DURING STANDBY OPERATION. |
| S-16C |
BATTERY CHARGER |
AUTOMATIC 2-STAGE BATTERY CHARGER WITH SPECIAL FEATURES THAT COMPLY WITH NAFPA-110 CERTIFICATION. |
| S-17 |
EMERGENCY STOP SWITCH |
"MUSHROOM" STYLE STOP SWITCH WITH KEY LOCK MOUNTED ON CONTROL PANEL (OPEN SET) OR ON EXTERNAL ENCLOSURE. |
| S-18 |
SENTINEL IV CONTROLLER |
LED DISPLAY CONTROLLER WITH ALL FEATURES OF SENTINEL III (STD. EQUIPMENT), PLUS FULL TELEMETRY SYSTEM FOR REMOTE OPERATION. NOTE: SPECIAL PRICE COMPENSATES FOR REPLACEMENT OF SENTINEL III WITH THE MORE SOPHISTICATED SENTINEL IV CONTROLLER. |
| S-19 |
REMOTE ANNUNCIATOR |
LED DISPLAY ANNUNCIATOR PROVIDES (10) ANNUNCIATIONS AND WORKS IN CONJUCTION WITH SENTINEL IV, FOR UP TO 150 FT. REMOTE LOCATION. |
| S-20 |
OUTPUT RELAY EXPANSION MODULE |
RELAY MODULE ALLOWS EXPANSION OF ALARM SIGNALS, ANNUNCIATION, OR OTHER SPECIAL CONTROL FUNCTIONS |
| S-22 |
COMBINATION RADIATOR AND OIL DRAIN |
AN OPEN-CLOSE VALVE WITH FEXIBLE DRAIN EXTENSION TUBE IS INSTALLED ON BOTH RADIATOR AND ENGINE OIL DRAIN SYSTEM. |
| S-26 |
ALARM SYSTEM INTERFACE |
SYSTEM CONSIST OF RUN (NORMAL OPERATION) RELAY AND FAIL/WARNING RELAY. THIS SYSTEM REQUIRES WIRING CONNECTIONS (FURNISHED BY OTHERS), TO THE SENTINEL III CONTROLLER AND AN AUDIBLE ALARM OR OTHER TYPE SIGNAL (ALSO FURNISHED BY OTHERS). |
ORDER INFORMATION: ADD THE ABOVE PART NUMBERS OF SELECTED ITEMS, TO THE MODEL NUMBER OF SELECTED GENERATOR SET. |