PART NO. |
PART |
DESCRIPTION |
|
CONSULT
CIRCUIT BREAKER SHEET |
CIRCUIT BREAKER USED
WITH 1 PHASE AND 3 PHASE GEN-SETS |
ALL SINGLE & THREE
PHASE MAIN
LINE CIRCUIT BREAKERS FROM 15 KW TO 200 KW IN 1800 RPM SETS, ARE SIZED
TO THE INDIVIDUAL KW OUTPUT OF GENERATOR. SEE
SEPARATE CIRCUIT BREAKER SHEET FOR SPECIFICATIONS. |
|
S-3 |
RESIDENTIAL 3 PHASE SETS WITH WINDING MODIFICATION |
3 PHASE OUTPUT FOR 3600 RPM, RESIDENTIAL SETS. INCLUDES 3-POLE CIRCUIT BREAKER. |
|
S-5 |
RESIDENTIAL WINDING MOD FOR 50 HERTZ |
MODIFY RESIDENTIAL SETS, TO PRODUCE 50 HERTZ. ADD THIS CHANGE TO BOTH 1 AND 3 PHASE WINDINGS ON ALL KW SIZES. |
|
S-6 |
MOUNTING PAD
33"WI X 38"LG X 2"HI |
RE-INFORCED, POLYETHYLENE (HDPE)
MOUNTING PAD FOR 8.5, 10.0, AND 12.0 KW RESIDENTIAL GEN-SETS. |
|
S-7 |
MOUNTING PAD
42"WI X 50"LG X 4" HI |
RE-INFORCED, POLYETHYLENE (HDPE)
MOUNTING PAD FOR 16.0 KW RESIDENTIAL GEN-SETS. |
|
SEE
FUEL TANK SHEET |
UL-142 CERTIFIED METAL
SUB-BASE
FUEL TANKS |
THE NORMAL BASE
MOUNTED, POLYETHYLENE FUEL TANKS, HAVE BEEN REPLACED WITH UL-142
CERTIFIED SINGLE WALL STEEL TANKS (STANDARD TANKS) AND DOUBLE WALL STEEL
TANKS (LEAK PROOF TANKS), DUE TO INCREASING DEMAND FOR UL CERTIFIED
TANKS. SEE SEPARATE FUEL TANK SHEET FOR SPECIFICATIONS. |
|
S-10 |
FLEXIBLE FUEL LINE |
FLEXIBLE FUEL LINE FOR
LPG OR NATURAL GAS FUELED GEN-SETS 7.5 KW - 40 KW. |
|
CONSULT
MUFFLER SHEET |
CRITICAL
MUFFLER & RESIDENTIAL MUFFLER EXTERIOR
& INTERIOR MOUNTING |
OUR STANDARD HOUSED
& OPEN GEN-SETS USE INDUSTRIAL GRADE SILENCERS, WHICH CAN BE
UPGRADED TO A RESIDENTIAL OR CRITICAL GRADE SILENCER. OUR SUPER-SILENT
HOUSED GEN-SETS USE RESIDENTIAL GRADE SILENCER, WHICH CAN BE UPGRADED TO
A CRITICAL SILENCER. ALL RESIDENTIAL GEN-SETS 7.5 -15 KW HAVE INTERIOR
MUFFLERS. GEN-SET SIZES 18—135 KW HAVE EXTERIOR MOUNTED MUFFLERS,
WHICH CAN BE MOUNTED IN THE INTERIOR FOR AN ADDITIONAL PRICE. |
|
SEE
SEPARATE MUFFLER UPGRADE SHEET FOR SPECIFICATIONS. |
|
S-12A |
ELECTRONIC GOVERNOR FOR
DIESEL ENGINES ONLY |
ALLOWS CLOSE ENGINE
SPEED AND FREQUENCY REGULATION TO 1/2%. NOTE ALL GM ENGINES HAVE
ELECTRIC GOVERNORS. |
15 KW - 60 KW |
|
S-12B |
75 KW - 130 KW |
|
S-13B |
ENGINE WATER HEATER
WITH THERMOSTAT |
WARMS ENGINE BLOCK FOR FASTER COLD WEATHER STARTING AND REDUCES CONDENSATION BUILD-UP WITHIN ENCLOSURE. BOTH HEATERS ARE ENERGIZED BY 120 VAC UTILITY POWER AND CONTROLLED BY THERMOSTAT, WHILE ON STANDBY MODE. |
15 KW - 46 KW |
|
S-13C |
60 KW - 130 KW |
|
S-14 |
BATTERY HEATER
WITH
THERMOSTAT |
HEATS BATTERY TO 60°F
ON 120 V. NORMAL POWER, WHILE GEN-SET IS IN STANDBY MODE. |
|
S-16A |
AUTO 12 VDC
BATTERY CHARGER RECOMMENDED FOR 7.5 THRU 15 KW GEN-SETS
|
CHARGER IS ALL ELECTRONIC (DIGITAL) AND
AUTOMATIC, PROVIDING 3-STAGE CHARGING: "BULK" (FAST
CHARGE), "ABSORPTION" (GRADUAL CHARGE REDUCTION), AND
"FLOAT" PROVIDING A LOW MAINTENANCE CHARGE, FOR LEAD ACID
BATTERIES. UL-1012 CERTIFIED
|
|
S-16B |
AUTO 12 VDC BATTERY CHARGER RECOMMENDED FOR 17.5 THRU 130 KW GEN-SETS
|
CHARGER IS TRANSFORMER CONTROLLED,
AUTOMATIC OPERATION WITH 20STAGE CHARGING: "BULK" (FAST
CHARGE) AND "FLOAT" (LOW MAINTENANCE CHARGE), FOR LEAD ACID AND
NICKEL-CADMIUM BATTERIES. UL-1012 CERTIFIED.
|
|
S-16C |
AUTO 12 VDC
BATTERY CHARGER RECOMMENDED FOR 17.5 KW - 200 KW AND WHERE
NAFPA 110 CERTIFICATION IS REQ.
|
CHARGER IS TRANSFORMER CONTROLLED,
AUTOMATIC OPERATION WITH 2-STAGE CHARGING: "BULK" (FAST CHARGE)
AND "FLOAT" (LOW MAINTENANCE CHARGE), FOR LEAD ACID AND
NICKEL-CADMIUM BATTERIES. UL-1012 CERTIFIED AND NAFPA 110 COMPLIANT.
|
|
S-17 |
EMERGENCY "MUSHROOM" STOP SWITCH
FOR OPEN END ENCLOSED STANDBY SETS
|
EMERGENCY SWITCH INSTALLED ON
"SENTINEL I" CONTROL PANEL, ON ALL SP & SPD "OPEN"
(NO ENCLOSURE) GEN-SETS.
|
|
EMERGENCY SWITCH INSTALLED ON OUTSIDE
ENCLOSURE FOR ALL SP & SPD ENCLOSED GEN-SETS.
|
|
S-18 |
SENTINEL IV WITH FULL
TELEMETRY SYSTEM FOR TOTAL REMOTE CONTROL FROM WORLD-WIDE LOCATIONS
|
ALL FEATURES OF SENTINEL III IS INCLUDED IN
THE SENTINEL II CONTROLLER PLUS FULL TELEMETRY CONTROL, BY USE OF A
COMMUNICATIONS SOFTWARE. THIS CONTROLLER CAN BE CONNECTED TO A PC, USING A
SPECIFIC 810 INTERFACE, AND A CUSTOMIZED MODEM. THIS SYSTEM ALLOWS
OPERATOR, FULL CONTROL AND ANNUNCIATION, ON ANY GROUP OF GEN-SETS, FROM AN
REMOTE LOCATION IN THE WORLD.
|
|
S-19 |
REMOTE ANNUNCIATOR FOR USE W/ SENTINEL III
& IV
|
LED DISPLAY ANNUNCIATOR PROVIDES (8)
ANNUNCIATIONS, PLUS (2) BOTTOM SPACES (TOTAL 10 SPACES) PROVIDED FOR FIXED
POSITIONS OF “LINK LOST” AND “POWER ON”. THIS IS A REMOTE
ANNUNCIATOR FOR SENTINEL III & IV, FOR USE UP TO 150 FT. REMOTE
LOCATION. (1800 RPM SETS ONLY)
|
|
S-20 |
OUTPUT RELAY EXPANSION
MODULE
|
EXPANSION MODULE ALLOWS UP TO (8) MORE
CONTACTS FOR ADDITIONAL ANNUNCIATING (SEE ANNUNCIATOR PART NO. S-19 OR
ADDITIONAL CONTROL FUNCTIONS, THAN NORMAL (3) FUNCTIONS ON SENTINEL III
& IV. (FOR 1800 RPM SETS ONLY)
|
|
CONSULT HOUSING
UPGRADE SHEET |
ALUMINUM HOUSING
UPGRADE
|
ALL SENTRY-PRO "STANDARD" AND
"SUPER-SILENT", WEATHER PROTECTED HOUSINGS FOR ALL KW SIZES, ARE
AVAILABLE AT ADDITIONAL COSTS. ALLOW 10-12 WEEKS SHIP TIME. SEE
SEPARATE ALUMINUM HOUSING UPGRADE SHEET FOR PART NUMBERS &
SPECIFICATIONS.
|
|
CONSULT ATS/ASE SECTION |
SWITCHGEAR
|
AUTOMATIC TRANSFER SWITCH (ATS) PLUS
COMBINATION AUTO TRANSFER SWITCH AND SERVICE ENTRANCE SWITCH (ASE),
PRE-WIRED AND INTO ONE ENCLOSURE. BOTH ATS & ASE SWITCHES HAVE
ENCLOSURES AVAILABLE IN NEMA-1, 3R, 4, AND 12.
|
|
S-22 |
COMBO RADIATOR & OIL DRAINS
|
INSTALL "OPEN/CLOSE" VALVE,
BARBED FITTING, AND FLEXIBLE HOSE EXTENSIONS WITH CAP.
|
|
ORDER INFORMATION: ADD
THE ABOVE PART NUMBERS OF SELECTED ITEMS, TO THE MODEL NUMBER OF
SELECTED GENERATOR SET. |